-Language-
When installing and debugging MC-5812T, it was found that the electric bolt lock did not have 12V voltage during the test
2017-11-30 16:34
Details of the problem:

Hello, when installing and debugging MC-5812T, what is the reason why the electric bolt lock has no 12V voltage during the test, and how to solve it?

Expert answer:

Hello, there is no voltage on the electric bolt lock, please check whether the wiring is missing or connected incorrectly. The +12V of the power supply is connected to the COM port of the controller, the positive pole of the electric bolt lock is connected to the NC of the controller, and the negative pole of the electric bolt lock is connected to the GND of the power supply.