-Language-
Simple Access Control Installation Requirements for Wires
2017-02-13 14:47
Details of the problem:

Ready to install a set of simple access control, want to know the wiring requirements, such as the specifications and limit lengths of signal wires, lock wires, and switch wires?

Expert answer:

Hello, thank you for using our company's products, the following are the recommended specifications:

AC220V AC power cord: use 3*1.0 square millimeter (or more) wire

Electric lock wire: use 2*1.0 square millimeter (or more) wire, the longest wiring distance does not exceed 50 meters

RS485 communication line: use 2*0.5 square millimeter (or more) wire, it is recommended to use shielded wire, the longest wiring distance does not exceed 1200 meters

TCP/IP communication cable: standard network cable, the longest wiring distance does not exceed 100 meters

Card reader cable: use 8*0.5 square millimeter (or more) wire, the longest wiring distance does not exceed 80 meters

Door sensor or door switch wire: use 2*0.5 square millimeter (or more) wire, the longest wiring distance does not exceed 100 meters